• Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network
  • Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network

Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network

Type: Boîte de Mesure de Distribution
Structure: Protection
Certificat: ISO9001: 2000, CCC
Forme: All-type emballé
Tension de fonctionnement: Basse Tension
Taille: 3 Uint

Contacter le Fournisseur

Membre Diamant Depuis 2022

Fournisseurs avec des licences commerciales vérifiées

Fabricant/Usine

Info de Base.

N° de Modèle.
YBM22-12/0.4-1600KVA
Gamme d′applications
Immeubles de Grande Hauteur
Matériel de Shell
Steel Plate
Shell Catégorie de protection
IP34
Marque
Sce
Marque Déposée
SCE
Origine
China
Code SH
8537201000
Capacité de Production
980 Sets/Year

Description de Produit

This series substation follows Standard: GB17467-1998; And relative IEC standard.
This substation is a combination of High Voltage Cabinet, Low Voltage Cabinet and Transformer.
 
Main Technical Parameters for HV Switchgear
No. Item Unit XGN-12(F) XGN-12(F. R) XGN15-12(F) XGN15-12(F. R)
1 Rated Voltage KV 12
2 Rated Insulation Level Rated Short-time Power-frequency Withstand Voltage KV Phase-to-ground Voltage & phase-to-phase Voltage: 42,
Disconnector Break Voltage: 48
Rated Lightning Impulse Withstand Voltage Phase-to-ground Voltage & phase-to-phase Voltage: 75,
Disconnector Break Voltage: 85
3 Rated Frequency Hz 50
4 Rated Current Main Busbar A 630
Load Switch 630 Depend on Fuse 630 Depend on Fuse
5 Rated Current of Fuse A   125   125
6 Rated Short-time Withstand Current   20
7 Rated Peak Withstand Current   50
8 Duration Time of Rated Short-time Withstand Current(Main Loop) S 3 3 3 3
9 Duration Time of Rated Short
time Withstand Current(Grounded Loop)
S 2 2 2 2
10 Rated Short-circuit Making Current KV 50
11 Rated Short-circuit Breaking Current KV   31.5(Prediction)   31.5(Prediction)
12 Rated Breaking Current Active-power Load Current A 630   630  
Close-loop Breaking Current A 630   630  
Cable Charging Current A 10 10 10 10
13 Rated Take-over Current A   3150    
14 Rated Transfer Current A       1700
15 Protection Degree     IP3X
16 Mechanical Endurance Times 1000 2000
Outdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution NetworkOutdoor 1600kVA Pre-Fabricated Substation for Urban and Rural Distribution Network

 

Envoyez votre demande directement à ce fournisseur

*De:
*A:
*Message:

Entrez entre 20 à 4000 caractères.

Ce n'est pas ce que vous recherchez? Publier la Demande d'Achat Maintenant

Vous Aimerez Aussi

Contacter le Fournisseur

Membre Diamant Depuis 2022

Fournisseurs avec des licences commerciales vérifiées

Fabricant/Usine
Nombre d'Employés
256
Année de Création
2006-11-09