• Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
  • Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
  • Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
  • Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
  • Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
  • Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer

Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer

Demande: Metering
Type: Transformateur de Courant
Phase: Unique
Opération Condition: De plein air
Usage: Protection, Mesures
Formulaire d′enroulement: Simple couche et type bien serré

Contacter le Fournisseur

Fabricant/Usine & Société Commerciale

Visite Virtuelle à 360

Membre Diamant Depuis 2019

Fournisseurs avec des licences commerciales vérifiées

Zhejiang, Chine
Coopéré avec Fortune 500
Ce fournisseur a coopéré avec des entreprises Fortune 500
Brevets attribués
Le fournisseur a attribué 4 brevets, vous pouvez consulter le Audit Report pour plus d'informations
Attestation de gestion
Le fournisseur possède une certification de système de gestion de la qualité, comprenant :
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Certification du produit
Les produits du fournisseur possèdent déjà les qualifications de certification pertinentes, notamment :
KEMA
pour voir toutes les étiquettes de résistance vérifiées (33)

Info de Base.

N° de Modèle.
LMZ-4
Milieu isolant
Résine époxy
Installation
Type Extension
Structure circuit magnétique
Un étage type
Tension principe de transformation
Électromagnétique à
altitude
ne doit pas dépasser 1000 m.
température ambiante
-5ºc~+40ºc
humidité relative de l′air
≤85 %
site relatif à l′air
intérieur.
Paquet de Transport
Export Box
Marque Déposée
DGG
Origine
China
Code SH
8504311000
Capacité de Production
100000PCS/Year

Description de Produit

Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.
Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
General

This type of transformer adopts an integral casting structure, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 0.66kV, used for current measurement, electric energy metering, relay protection, etc.
It complies with the standard Q/GDW1572-2014 Technical specification of a low-voltage current transformer for metering.


Use environment 
  1. Altitude: should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air relative humidity:≤85%
  4. Air relative site: indoor.
Technical parameter
  1. Rated secondary current: 5A or 1A
  2. Power factor: cosφ=0.8(lag)
  3. Rated frequency: 50Hz or 60Hz
  4. Rated primary current, rated output, and accurate level see table 1
  5. Insulating property: primary winding to secondary winding and ground, and secondary winding to the ground can bear the power frequency withstand voltage 3kV for 1min.

Technical ratio
 
Type Rated primary current(A) Rated output VA(COS  phi=0.8lag)
    0.2S 0.2 0.5S 0.5 1
LFZ1D-DGG1 10-60 5-2.5 5-2.5 5-2.5 5-2.5 5-2.5
LMZ(1D,2D)-DGG1 75-500 5-2.5 5-2.5 5-2.5 5-2.5 5-2.5
LMZ(3D,4D)-DGG1 600-1500 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75

Our Customer

Our customers are located all over the world.
Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
Test Reports
All products have undergone professional testing and certification.
Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current TransformerElectric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current TransformerPhotos of Product
Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer
Eng. ADOFO MICHAEL ADJEI / BSc, MSc
Project Manager, Foreign Trade and Technology
Denggao Electric Co. Ltd
Head Office: No 208 Weiwu Lu, Economic Development Zone. Yueqing - China

Envoyez votre demande directement à ce fournisseur

*De:
*A:
*Message:

Entrez entre 20 à 4000 caractères.

Ce n'est pas ce que vous recherchez? Publier la Demande d'Achat Maintenant

Trouver des Produits Similaires par Catégorie

Page d'Accueil du Fournisseur Produits Transformateur Transformateur de courant basse tension Electric Power Instrument Zero Phase Split Core Low Voltage/Potential CT PT Current Transformer