High Cop Air Cooled Heat Pump with Shell and Tube Evaporator

Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification: CE

Contacter le Fournisseur

Membre Diamant Depuis 2015

Fournisseurs avec des licences commerciales vérifiées

Évaluation: 5.0/5
Fabricant/Usine & Société Commerciale

Info de Base.

N° de Modèle.
ESGA-130DHTN
compresseur de pompe à chaleur
sonnette de taïwan
détendeur de pompe à chaleur
emerson
filtre sec de la pompe à chaleur
danfoss
Paquet de Transport
Standard Export Package
Spécifications
CE
Marque Déposée
Eurostars
Origine
Guangdong, Prc
Code SH
8418692090
Capacité de Production
2000PCS/Year

Description de Produit

1.Brief introduction-Eurostars air cooled air source heat pump
a)Ambient temp range:-5~43C(-25C~43C)
b)Intellectualized control system and Low Noise
c)High Efficient and Energy Saving
d)Easy Operation and Installation
e)Compact Exterior
f)High quality
g)Competitive price

2.Unit Features-Eurostars air cooled air source heat pump
1).Heating capacity ranged from 130Kw to 790 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc
6). Strong unit base frame ensured the equipment stable operation
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.


3.Technical parameter-air cooled air source heat pump
Please ask salesman for detailed complete data or visit our website.

Air Cooled Chiller Unit Heat Pump (Screw Type Compressor-one compressor)
Model ESGA- 30SHTN 40SHTN 55SHTN 65SHTN 75SHTN 85SHTN 90SHTN
Rated Cooling Capacity Cooling Capacity (KW) 111 161 215 254 294 321 346
Cooling Capacity (USRT) 31.57 45.79 61.15 72.24 83.62 91.30 98.41
Comp. Input Power (KW) 34.6 48.2 63.8 70.5 82.4 90.2 98.9
Rated Heating Capacity Heating Capacity (KW) 122 174 232 269 311 341 369
Heating Capacity (USRT) 34.70 49.49 65.98 76.51 88.45 96.99 104.95
Comp. Input Power (KW) 34.1 47.4 62.8 69.2 80.8 88.4 97.2
Refrigerant R407C
Power Supply 3φ-380V/50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp. protection, Low & High pressure protection,
Low temp. protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 1
Capacity Control (%) 0, 66, 100 0, 50, 75, 100
Refrigerant Charge (Kg) 30 42 56 68 78 84 93
Air Cooled Heat Exchanger Ripple Aluminum Fins Around Copper Pipe
Water Cooled
Heat Exchanger
Dia.of Pipe (inch) 2-1/2" 3" 3" 3" 4" 4" 4"
Water Side Max Pressure (MPa) 1
Chilled Water Flow(m3/h) 19.09 27.69 36.98 43.69 50.57 55.21 59.51
Water Pressure Drop (kPa) 28 33 48 55 61 64 66
Flow of Hot Water(m3/h) 20.98 29.93 39.90 46.27 53.49 58.65 63.47
Axial Fan Air Flow×1000m3/h 56.8 80.4 85.2 120.6 120.6 160.8 160.8
Power×Qty (KW) 1.2×4 2.0×4 1.2×8 1.2×8 1.2×8 2.0×8 2.0×8

Air Cooled Chiller Unit Heat Pump (Screw Type Compressor-two compressor)
Model ESGA- 100DHTN 110DHTN 130DHTN 140DHTN 150DHTN 165DHTN 180DHTN
Rated Cooling Capacity Cooling Capacity (KW) 392 439 509 537 588 642 693
Cooling Capacity (USRT) 111.49 124.86 144.77 152.73 167.24 182.59 197.10
Comp. Input Power (KW) 116.4 127.6 141.0 148.2 164.8 180.4 197.8
Rated Heating Capacity Heating Capacity (KW) 424 464 538 568 624 682 740
Heating Capacity (USRT) 120.59 131.97 153.01 161.55 177.47 193.97 210.47
Comp. Input Power (KW) 114.4 125.6 138.3 145.4 161.7 176.9 194.4
Refrigerant R407C
Power Supply 3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp. protection, Low & High pressure protection,
Low temp. protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 2
Capacity Control (%) 0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg) 114 122 146 150 164 178 196
Air Cooled Heat Exchanger Ripple Aluminum Fins Around Copper Pipe
Water Cooled
Heat Exchanger
Dia.of Pipe (inch) 5" 5" 3"×2 3"×2 4"×2 4"×2 4"×2
Water Side Max Pressure (MPa) 1
Chilled Water Flow(m3/h) 67.42 75.51 87.55 92.36 101.14 110.42 119.20
Water Pressure Drop (kPa) 42 54 44 52 54 55 65
Flow of Hot Water(m3/h) 72.93 79.81 92.54 97.70 107.33 117.30 127.28
Axial Fan Air Flow×1000m3/h 160.8 160.8 172.8 241.2 230.4 321.6 321.6
Power×Qty (KW) 1.2×12 1.2×12 2.0×12 2.0×12 1.2×16 2.0×16 2.0×16


1. Rated Cooling Capacity Based on: DB Temperature 35ºC/WB Temperature 24ºC;Chilled water in/outlet temp. 12ºC/7ºC, Fouling factor: 0.088.°C/KW.
2. Rated Cooling Capacity Based on: DB Temperature 7ºC/WB Temperature 6ºC;Hot water in/outlet temp. 40ºC/45ºC; Hot water range: 45ºC~50ºC;

4.Quotation Remarks-air cooled air source heat pump
1.Packing: Standard export package
2.Delivery Day: 35 working days after deposit is confirmed
3.Delivery term: CIF,FOB or CNF EX-Work are welcomed
4.Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
Or 100% Irrevocable non-transferred LC at sight
5.Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
6.Validity: 20 days
7.Payment currency: USD

























Envoyez votre demande directement à ce fournisseur

*De:
*A:
*Message:

Entrez entre 20 à 4000 caractères.

Ce n'est pas ce que vous recherchez? Publier la Demande d'Achat Maintenant

Vous Aimerez Aussi

Contacter le Fournisseur

Membre Diamant Depuis 2015

Fournisseurs avec des licences commerciales vérifiées

Évaluation: 5.0/5
Fabricant/Usine & Société Commerciale
Conditions de Paiement
LC, T/T
Disponibilité OEM/ODM
Yes