• 11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable
  • 11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable
  • 11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable
  • 11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable
  • 11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable
  • 11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable

11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable

Demande: Construction , Souterrain , Centrale
Tension: Câble à Tension Base & Moyen
Courant: Câble à AC
Matériau isolant: xlpe
Matériau de la gaine: pvc
Forme Matériel: Fil rond

Contacter le Fournisseur

Membre Diamant Depuis 2015

Fournisseurs avec des licences commerciales vérifiées

Fabricant/Usine & Société Commerciale

Info de Base.

N° de Modèle.
YJV32 YJLV32
Certificat
ISO
nom du produit
câble d′alimentation 11 kv
standard
iec60502
tension de débit
11 kv 15 kv 33 kv
conducteur
cuivre ou aluminium
l′isolation
xlpe
gainé
pvc
armure
blindage de fil d′acier ruban d′acier blindage de fil d′aluminium
taille
185mm2
certificat
psb tuv
Paquet de Transport
Standard Export Drum
Spécifications
iec60502
Marque Déposée
RNE DA
Origine
Hebei, China
Code SH
85444921
Capacité de Production
500km/Month

Description de Produit


 
33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Power Cable

1 Application:
 It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting.

Standard: BS6622, BS EN/IEC 60228,IEC60502.2
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622
Filler: PET (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armouring:

Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Colour: Red or Black

2. Using features :Medium Voltage Power Cable Underground 11kv 15kv 33kv XLPE Power Cable

1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius:Single core - Fixed: 15 x overall diameter;3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
Note:The single core armoured cables are used for D.C. system only. If used for A.C. system, the magnetic isolation should be applied on the steel armor wires of non-magnetical materials should be used.
11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable



11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable


 

 

Envoyez votre demande directement à ce fournisseur

*De:
*A:
*Message:

Entrez entre 20 à 4000 caractères.

Ce n'est pas ce que vous recherchez? Publier la Demande d'Achat Maintenant

Trouver des Produits Similaires par Catégorie

Page d'Accueil du Fournisseur Produits Câble Électrique 11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable

Vous Aimerez Aussi

Contacter le Fournisseur

Membre Diamant Depuis 2015

Fournisseurs avec des licences commerciales vérifiées

Fabricant/Usine & Société Commerciale
Certification du Système de Gestion
ISO9001:2015, ISO14001:2015, Autres