3Les phases/50Hz/400 V/PF=0,8 | 3Les phases/60Hz/440V/PF=0,8 | |||||||
Modèle | KW (PR) | KVA(PR) | KW(ESP) | KVA(ESP) | KW(PR) | KVA(PR) | KW(ESP) | KVA(ESP) |
S164G65B1 | 6.5 | 8.1 | 7 | 8.8 | 7.8 | 9.8 | 8.4 | 10.5 |
S164G88B2 | 8.8 | 11 | 9.5 | 11.9 | 10.6 | 13.2 | 11.4 | 14.3 |
S164G108B3 | 10.8 | 13.5 | 11.8 | 14.8 | 13 | 16.2 | 14.2 | 17.7 |
S164G128C4 | 12.8 | 16 | 14 | 17,5 | 15.4 | 19.2 | 16.8 | 21 |
S164G14C5 | 14 | 17,5 | 15.4 | 19.3 | 16.8 | 21 | 18.5 | 23.1 |
S184G16C6 | 16 | 20 | 17.6 | 22 | 19.2 | 24 | 21.1 | 26.4 |
S184G18D7 | 18 | 22,5 | 20 | 25 | 21.6 | 27 | 24 | 30 |
S184G20D8 | 20 | 25 | 22 | 27.5 | 24 | 30 | 26.4 | 33 |
S184G22D9 | 22 | 27.5 | 24,8 | 31 | 26.4 | 33 | 29.8 | 37.2 |
S184G25D10 | 25 | 31.25 | 28 | 35 | 30 | 37,5 | 33,6 | 42 |
S184G28E11 | 28 | 35 | 31 | 38,75 | 33,6 | 42 | 37.2 | 46,5 |
S184G30E12 | 30 | 37,5 | 33 | 41,25 | 36 | 45 | 39,6 | 49.5 |
S184G32E13 | 32 | 40 | 35 | 43,8 | 38,4 | 48 | 42 | 52,5 |
S224G32B1 | 32 | 40 | 35,2 | 44 | 38,4 | 48 | 42.2 | 52,8 |
S224G34B2 | 34 | 42,5 | 37,4 | 46,8 | 40,8 | 51 | 44,9 | 56.1 |
S224G40B3 | 40 | 50 | 44 | 55 | 48 | 60 | 52,8 | 66 |
S224G45B4 | 45 | 56,3 | 49.5 | 61,9 | 54 | 67,6 | 59,4 | 74.4 |
S224G50C5 | 50 | 62,5 | 55 | 68,8 | 60 | 75 | 66 | 82,5 |
S224G54C6 | 54 | 67,5 | 59,4 | 74,3 | 64,8 | 81 | 71,3 | 89,1 |
S224G58C7 | 58 | 72.5 | 65 | 81,3 | 69,6 | 87 | 76.5 | 95,7 |
S224G64D8 | 64 | 80 | 70 | 87,5 | 76,8 | 96 | 84,5 | 105.6 |
S224G68D9 | 68 | 85 | 75 | 93,8 | 81,6 | 102 | 89,8 | 112,2 |
S224G75D10 | 75 | 93,8 | 82,5 | 103,1 | 90 | 112,5 | 99 | 123,8 |
S274G80B1 | 80 | 100 | 88 | 110 | 96 | 120 | 106 | 132 |
S274G90B2 | 90 | 112,5 | 99 | 123.75 | 108 | 135 | 119 | 149 |
S274G100B3 | 100 | 125 | 110 | 137,5 | 120 | 150 | 132 | 165 |
S274G112C4 | 112 | 140 | 122 | 152,5 | 134 | 168 | 147 | 185 |
S274G120C5 | 120 | 150 | 132 | 165 | 144 | 180 | 158 | 198 |
S274G128C6 | 128 | 160 | 140 | 175 | 154 | 192 | 169 | 211 |
S274G140C7 | 140 | 175 | 154 | 192.5 | 168 | 210 | 185 | 231 |
S274G150D8 | 150 | 187,5 | 165 | 206.25 | 180 | 225 | 198 | 248 |
S274G160D9 | 160 | 200 | 176 | 220 | 192 | 240 | 211 | 264 |
S274G180E10 | 180 | 225 | 196 | 245 | 216 | 270 | 238 | 297 |
S274G200E11 | 200 | 250 | 220 | 275 | 240 | 300 | 264 | 330 |
S314G200D1 | 200 | 250 | 220 | 275 | 240 | 300 | 264 | 330 |
S314G220D2 | 220 | 275 | 242 | 303 | 264 | 330 | 290 | 363 |
S314G240D3 | 240 | 300 | 264 | 330 | 288 | 360 | 305 | 381 |
S314G250D4 | 250 | 313 | 275 | 344 | 300 | 375 | 330 | 413 |
S314G260D5 | 260 | 325 | 286 | 358 | 312 | 390 | 343 | 429 |
S314G280D6 | 280 | 350 | 308 | 385 | 336 | 420 | 370 | 462 |
S314G300E7 | 300 | 375 | 330 | 413 | 360 | 450 | 396 | 495 |
S314G320E8 | 320 | 400 | 352 | 440 | 384 | 480 | 422 | 528 |
S314G360E9 | 360 | 450 | 396 | 495 | 432 | 540 | 474 | 593 |
S354G360D1 | 360 | 450 | 396 | 495 | 432 | 540 | 475 | 594 |
S354G400D2 | 400 | 500 | 440 | 550 | 480 | 600 | 528 | 660 |
S354G430D3 | 430 | 538 | 473 | 592 | 516 | 646 | 568 | 711 |
S354G450D4 | 450 | 563 | 495 | 619 | 540 | 676 | 594 | 744 |
S354G480D5 | 480 | 600 | 528 | 660 | 576 | 720 | 634 | 792 |
S354G500D6 | 500 | 625 | 550 | 688 | 600 | 750 | 660 | 825 |
S354G520E7 | 520 | 650 | 572 | 715 | 624 | 780 | 686 | 858 |
S354G540E8 | 540 | 675 | 594 | 743 | 648 | 810 | 713 | 891 |
S354G560E9 | 560 | 700 | 616 | 770 | 672 | 840 | 739 | 924 |
S354G600E10 | 600 | 750 | 660 | 825 | 720 | 900 | 792 | 990 |
Série de svc de la technologie sans balai de alternateurs - Stamford | ||||||||||
La taille de trame (mm) | Châssis 044-734 | |||||||||
KVA | À partir de 7kVA - jusqu'à 2500kVA | |||||||||
Tension nominale | 220V, 380V, 400V, 415V, 440V | |||||||||
Fréquence nominale | 50Hz/60Hz | |||||||||
La classe de protection Et l'isolement de la classe | IP21, IP23, classe H | |||||||||
Pôles | 2 - 4 | |||||||||
Température d'air de refroidissement | 258-313K(-15 ºC-40ºC) | |||||||||
Indice de performance du principal | ♦trois phase quatre threads ♦Réglage de taux de tension stable ≤ ± 1 % ♦état transitoire de la tension ≤ -15 % ~ +20% ♦vague d'aberration du taux de ≤ 2 % THD de tension ♦Téléphone harmonie vague facteur de ≤ 2 % de THF de téléphone ♦facteur efficace de téléphone téléphone TIF ≤ 2 % | |||||||||
Fonctionnalités | ♦fiable système passionnant et facultatifs AVR système magnétique permanent toujours fournir à toutes les occasions d'excitation invariable. ♦facile d'être connecté avec l'alimentation réseau d'autres génératrices parallèle. ♦rotor équilibré, scellé simple et double roulements à billes. ♦pratique et facile d'installation de l'entretien, un accès facile à la borne. rotation| et vis d'accouplement du redresseur. ♦large gamme d'adaptateur de bride et l'Accouplement disque pour un seul palier. ♦En conformité avec tous les mainland standard. | |||||||||
En option | ♦Les adaptateurs et disque d'entraînement interchangeables ♦phase unique ♦Réglage de la tension à distance ♦Classe de protection IP23 ♦Les chaufferettes ♦thermistances | |||||||||
Les champs des applications | Pour être équipés sur générateur diesel set, ou alimentation de secours en fournissant en continu. |
Fournisseurs avec des licences commerciales vérifiées