Info de Base.
Description de Produit
Electrophoresis special refrigeration equipment (1) chiller transportation moving should make the necessary protective measures, rainproof bull. (2) machine in handling process, loading and unloading car should be light, avoid touch attack. Second, the machine is installed (1) the machine should be installed in the well ventilated, dry, no air pollution, and environmental temperature, no more than 45 ° indoor, installation position to balance.(2) the in-out water chillers, circulation cooling water pipes, matching correctly, reasonable design, reasonable design connection not leak.(3) from surrounding walls refrigerating not less than 45CM blockage. Third, the power connector (1) the machine adopts three-phase four-wire, power, (R, S, T) 380V power lines (N), and meet up neutral grounding wire connection "correct".(2) the power generator voltage: 380V ± 10%. Electricity frequently rate: isolator ± 2%(3) power supply voltage fluctuation, cannot start the machine transducer, such as forced open machines to bring the machine, the company does not damage the responsibility.(4) control of the machine, the electrical appliances chain circuit arbitrarily change, it shall be the client needs to change in the company, the company, or until after checking contents alter line again, otherwise, the company inform the client does not bear the consequences of after the changes. Four, the machine operation (1) before starting around carefully check whether there is abnormal, wire connection, whether it is right, tighten conduit installation is correct, the voltage is normal.(2) open valve, check automatic water chillers tank has been filled with water (whether to check the cooling tower, water pump, water condenser circulating system until the water full without water or water do not run).(3) turn on the power switch, watch the lights on the panel, and display, pump has a thermometer on the job, and the thermometer, little also host to delay 4 minutes on it again. Five, temperature adjustment Operational guidelinesThe lights on the thermometer from top to bottom of the table meaning function: Bright lights flashingTemperature limit set limit temperatureLower temperature limit temperature settingemptyRefrigeration compressor boot is protected. Delay How to set upper temperature?At the same time in two key, enter temperature limit state, digital display Settings display temperature to limit temperature (" thickening 0.1 ° c ", "button 0.1 ° c," button to reduce down more than 0.5 seconds is quick put reduced). After the completion of the upper temperature setting, and according to the key to store the data. According to the same methods set temperature limit. Note that "> upper limit controller this rule.Note: 1, in the status, if not connected 5 seconds, automatic exit status.2, the heart must exit status to ensure that data will be stored. If the electricity, didn't quit before setting value may not be preserved.* basic working principletemperature control Temperature control according to the "upper" and "lower temperature, temperature" two parameters hypotheses "limit for 20 degrees Celsius temperature", "lower temperature" for 18 degrees Celsius, when the temperature control of temperature probe on perceived than 20 ° c j-t until the temperature is below 18 degrees temperature control, will stop refrigeration in 18 degrees - 20 ° c.When the extended compressor bootThere is a "controller", when the timer compressor stop timing starts when stop compressor, the first check before starting compressor, if has the timer with four minutes to start compressor, if dissatisfied with four minutes as four minutes is restarted. This can be restarted after stopping guarantee interval 4 minutes, prevent frequently damage compressor.Another controller of electricity within four minutes, just won't start compressor, this call again in electricity situation also can protect the compressor. (note: compressor in the time when extended protection on the above assumptions, adjustable Settings for four minutes). 6 and failure analysis, and simple questions processing method (1) panel indicatorName state processing method Phase failureLight (1) the power supply voltage is not normal, or the power of a photograph investigations(2) the power R, S, T sequence of two lines, exchange of position System fault not bright says input circuit is normal Bright, ventilated and undesirable heat that should check whether the machine is water-cooled (the obstacles to check, cooling tower, water pump, not the condenser circulating system is normal operation thereof, according to the problems after) inside the machine pressure switch (two little red dot) reset. Host system fault not light Light (1) from ac contactor to check whether the power cord connecting main compressor normal (2) host has damaged (please check technicians specialized refrigeration), Pump failureLight (1) for a long time when the pump's live (for supplemental pump start-up),(2) host water pump has been damaged, replace or pump. A host running on normal workDon't light didn't boot, or control in delay Note: if the equipment failure, please press the check cannot be excluded, if the company or professional please contact: no refrigeration technician experience cut from further loss. Seven, the daily maintenance and maintenance (1) every time before starting the check whether there is abnormal things around letter voltage, water pump, water pipe flow, whether there is water, cooling water circulation outside is normal or not.(2) chiller every operation period, usually two to three months, according to the heat transfer air-filled type to clean, water-cooled to clean with clear water cooling towers.(3) annually to do a big maintenance, do a machine maintenance and cleaning up.(4) advice in a professional technicians with refrigeration equipment maintenance etc.Electrophoresis special refrigeration equipment A machine (1) chiller transportation moving should make the necessary protective measures, rainproof bull. (2) machine in handling process, loading and unloading car should be light, avoid touch attack. Second, the machine is installed (1) the machine should be installed in the well ventilated, dry, no air pollution, and environmental temperature, no more than 45 ° indoor, installation position to balance.(2) the in-out water chillers, circulation cooling water pipes, matching correctly, reasonable design, reasonable design connection not leak.(3) from surrounding walls refrigerating not less than 45CM blockage. Third, the power connector (1) the machine adopts three-phase four-wire, power, (R, S, T) 380V power lines (N), and meet up neutral grounding wire connection "correct".(2) the power generator voltage: 380V ± 10%. Electricity frequently rate: isolator ± 2%(3) power supply voltage fluctuation, cannot start the machine transducer, such as forced open machines to bring the machine, the company does not damage the responsibility.(4) control of the machine, the electrical appliances chain circuit arbitrarily change, it shall be the client needs to change in the company, the company, or until after checking contents alter line again, otherwise, the company inform the client does not bear the consequences of after the changes. Four, the machine operation (1) before starting around carefully check whether there is abnormal, wire connection, whether it is right, tighten conduit installation is correct, the voltage is normal.(2) open valve, check automatic water chillers tank has been filled with water (whether to check the cooling tower, water pump, water condenser circulating system until the water full without water or water do not run).(3) turn on the power switch, watch the lights on the panel, and display, pump has a thermometer on the job, and the thermometer, little also host to delay 4 minutes on it again. Five, temperature adjustment Operational guidelinesThe lights on the thermometer from top to bottom of the table meaning function: Bright lights flashingTemperature limit set limit temperatureLower temperature limit temperature settingemptyRefrigeration compressor boot is protected. Delay How to set upper temperature?At the same time in two key, enter temperature limit state, digital display Settings display temperature to limit temperature (" thickening 0.1 ° c ", "button 0.1 ° c," button to reduce down more than 0.5 seconds is quick put reduced). After the completion of the upper temperature setting, and according to the key to store the data. According to the same methods set temperature limit. Note that "> upper limit controller this rule.Note: 1, in the status, if not connected 5 seconds, automatic exit status.2, the heart must exit status to ensure that data will be stored. If the electricity, didn't quit before setting value may not be preserved.* basic working principletemperature control Temperature control according to the "upper" and "lower temperature, temperature" two parameters hypotheses "limit for 20 degrees Celsius temperature", "lower temperature" for 18 degrees Celsius, when the temperature control of temperature probe on perceived than 20 ° c j-t until the temperature is below 18 degrees temperature control, will stop refrigeration in 18 degrees - 20 ° c.When the extended compressor bootThere is a "controller", when the timer compressor stop timing starts when stop compressor, the first check before starting compressor, if has the timer with four minutes to start compressor, if dissatisfied with four minutes as four minutes is restarted. This can be restarted after stopping guarantee interval 4 minutes, prevent frequently damage compressor.Another controller of electricity within four minutes, just won't start compressor, this call again in electricity situation also can protect the compressor. (note: compressor in the time when extended protection on the above assumptions, adjustable Settings for four minutes). 6 and failure analysis, and simple questions processing method (1) panel indicatorName state processing method Phase failureLight (1) the power supply voltage is not normal, or the power of a photograph investigations(2) the power R, S, T sequence of two lines, exchange of position System fault not bright says input circuit is normal Bright, ventilated and undesirable heat that should check whether the machine is water-cooled (the obstacles to check, cooling tower, water pump, not the condenser circulating system is normal operation thereof, according to the problems after) inside the machine pressure switch (two little red dot) reset. Host system fault not light Light (1) from ac contactor to check whether the power cord connecting main compressor normal (2) host has damaged (please check technicians specialized refrigeration), Pump failureLight (1) for a long time when the pump's live (for supplemental pump start-up),(2) host water pump has been damaged, replace or pump. A host running on normal workDon't light didn't boot, or control in delay Note: if the equipment failure, please press the check cannot be excluded, if the company or professional please contact: no refrigeration technician experience cut from further loss. Seven, the daily maintenance and maintenance (1) every time before starting the check whether there is abnormal things around letter voltage, water pump, water pipe flow, whether there is water, cooling water circulation outside is normal or not.(2) chiller every operation period, usually two to three months, according to the heat transfer air-filled type to clean, water-cooled to clean with clear water cooling towers.(3) annually to do a big maintenance, do a machine maintenance and cleaning up.(4) advice in a professional technicians with refrigeration equipment maintenance etc.
Adresse:
Building 3, Furong Xinda Technology Park, Shajing Town, Baoan District, Shenzhen
Type d'Entreprise:
Fabricant/Usine
Gamme de Produits:
Jouets, Machinerie de Fabrication & de Façonnage, Pièces & Accessoires d'Auto et de Moto, Produits Chimiques, Sports & Loisirs, Électricité & Électronique, Équipement Industriel & Composants
Certification du Système de Gestion:
ISO 9001
Présentation de l'Entreprise:
Shenzhen Yuehuihuang Automation Equipment Co., Ltd. est un professionnel de la fabrication de revêtement électrophorétique, especialized dans la fabrication de revêtement électrophorétique plus de dix ans, ce qui est devenu le meilleur chef de file de revêtement électrophorétique domaines et un des plus excellent revêtement électrophorétique de l′équipement des entreprises. Notre entreprise capital enregistré de 500 millions de dollars, ayant plus de 70 professionnels des personnes qui sont au service à l′étranger à long terme. Nos produits sont distribués à la Corée du Sud, le Vietnam, russe et plus de 10 pays et régions. YueHuiHuang fournir les produits de première classe, de la qualité et de service, strictement conforme à ISO9001. Offrir un guichet unique pour le client, par exemple, en sélectionnant le modèle de l′électrophorèse de l′équipement, de la planification, conception, installation, le débogage, optioning revêtements électrophorétique, d′épreuvage et la formation de la technologie.
Notre entreprise de fabrication du matériel de headquater est situé dans la province de Guangdong et de la fabrication de peinture est situé dans la province de Zhejiang. La société a un système de réseau après-vente et dans les zones à forte intensité de la clientèle comme Guangzhou Panyu, Shandong Weifang, de Liaoning à Shenyang, Zhejiang Wenzhou, Henan Zhengzhou, Luoyang, Shaanxi Xi′an, Hebei Shijiazhuang Shaodong Xinle, Hunan, Sichuan Chengdu, sont équipées de points de service après-vente ou la direction générale des subordonnés de commettre pour résoudre les problèmes du client en peu de temps. À présent, notre entreprise est non seulement le service en Chine, mais aussi s′étendre à l′étranger.
Notre avantage: Nous l′expérience une variété de cas d′ingénierie et en se fondant sur le résumé de continuer à développer et améliorer tous les équipements auxiliaires selon le besoin du client et pour atteindre tous les la production indépendante. Nous nous engageons à résoudre tous les problèmes découlant du processus de l′utilisation des clients pour l′équipement et le revêtement est la fabrication par nous-mêmes.
Nos domaines : Après de nombreuses années de dur travail et de la pratique, nous avons fait une percée technologique critique dans la lame de scie électrophorèse et alignement des roues. L′équipement nous Planification et conception, la lame de scie et le moyeu munufacturing par électrophorèse avancée recevoir les éloges des clients tant à la maison et à l′étranger. En même temps dans les pièces automobiles, machines agricoles, de tricycle, un camion léger véhicule spécial décoration de portes et fenêtres, moteurs et autres matériels accessoires l′industrie a une excellente performance, et a de nombreux cas de succès dans l′industrie correspondante l′analyse comparative des entreprises.
Nos idées : nous nous efforçons de qualité et de l′innovation dans nos produits, constamment introduire de nouvelles et haut de la science et technologie, de renforcer la gestion de l′entreprise, améliorer la formation du personnel, contrôle de la qualité des données, concept de design parfait, de haute qualité pré-vente, le service après-vente. Entreprise de maintenir la philosophie d′affaires de l"innovation scientifique et technologique, l′excellence, le développement durable, de bonne foi " de service