Précision: ¡À0.2-0.5%
Application principale: Eau, Eaux usées, Carburant diesel, Mazout
Taille: DN100-500
Capteur: Tube/Bride

Contacter le Fournisseur

Visite Virtuelle à 360

Membre Diamant Depuis 2009

Fournisseurs avec des licences commerciales vérifiées

Société Commerciale

Info de Base.

N° de Modèle.
flow meter
Demande
La production industrielle
Type
Débitmètre électromagnétique
Médias mesure
Liquide
Principe de mesure
Électrique
Objet Mesure
Pipeline fermé
Certificat
JIS, DIN, ANS, GB, CE, RoHS, ISO
temp. max
180c
taille max
2000mm
pression
4 mpa
certificat
iso, ce, sgs
Paquet de Transport
Carton/Polywood Case /Wood Case
Spécifications
CE/SGS/ISO
Marque Déposée
GN
Origine
Shanghai China
Code SH
9026100000
Capacité de Production
1000PCS/Month

Description de Produit

Wall-Mounted Ultrasonic Flow Meter with Lower Price

Wall-Mounted Ultrasonic Flow Meter With Lower Price

This technology of magnetic electromagnetic flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes' diameter, and are therefore designed such that they do not disturb or restrict the flow of the medium under measurement. As the sensors are not directly immersed in the liquid-there are no moving parts-there are no wear and tear concerns.

The method of magnetic electromagnetic flowmeter measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of conductive fluid-with no additional correction. This is a significant advantage that other types of flow meters don't have.

what's the technical parameters of magnetic electromagnetic flowmeter?

Production Name  magnetic electromagnetic flowmeter
 Medium  water;wastewater;Mud and varioue kinds of conductivity liquid
 Diameter  DN10~DN2000mm
 Accuracy  +/-0.5%
 Temperature  <80ºC(rubber); <180ºC(PTFE)
Pressure  4.0Mpa(DN10~80);1.6Mpa(DN100~150);1.0Mpa(DN200~1000);0.6Mpa(DN1200~2000)
 Flow speed  0.3~10m/s
 Requirement of   pipeline  Upstream ≥5DN;Downstream≤3DN
 Electrode  Stainless steel 316L(standard);Titanium;Tantalum;Hastelloy
 Lining  PTFE;Rubber
 Connection  Flange;thrad;clamp on
 Body material  Cast steel ;stainless steel 
 Power supply  220V;24V;Battery
 Output  Pulse;4~20mA;HART;RS485;MODBUS;GPRS
 Communication  HART;RS485;MODBUS
 Explosion proof  Customized 
 Protection  IP65 or IP68
 Environment  Environment:-20~60ºC
 Power  <20W

Wall-Mounted Ultrasonic Flow Meter with Lower Price

 Item  The Electrode table
 Material  The Medium
 SS316L   For:Living water; wastewater;Corrovise water and Mud,etc;
 Hastelloy B   For:Non-oxidizing acids at concentrations less than 10%;NAOH Concentrations less than 50%
 Hastelloy C   For:Mixed Acid and Oxidizing salts
 Titanium   For: Salt and weak acid ;Not application:hydrochloric acid, nitric acid and other reducing acids
 Tantalum   For:hydrochloric acid(<40%);Sulfuric acid and Other oxidizing acids
 Plantinum   For:Almost all acid-base salt solution But not application for aqua regia, except ammonium salt
Tungsten carbide   For:Pulp ;sewage ;slurry

Wall-Mounted Ultrasonic Flow Meter with Lower Price
Wall-Mounted Ultrasonic Flow Meter with Lower Price

[Installation]

 1.Installation location

  • Avoid the magnetic objects and equipment with stong electromagnetoc field;
  • should installa the flow meter at ventilated location;
  • Avoid the location wherer ambient temperature above 50ºC and relative humidity above 90%;
  • The water flowmeter should be installaed at somewhere spacious;
  • The DH1000 series Digital Electromagnetic Water Flow Meter with RS485 Signal should be installaed behind pump and the value should installa at downstream.            

    2.Installa the flow sensor

  • Must to ensure the pipeline is fulled and without bubbles to keep the high accuracy;
  • The flow direction shoudl keep with sign on the body of flowmeter;
  • Ensure the double electrodes keep Horizontal;
  • If the medium is mixed by liquid and solid,Pls installa it at vertical to extend the working life of lining;
  • If the environment with shocked pls installa the bracket at both front and behind;
  • If the medium is pollution liquid,should installa the flow meter at bypass pipe and don't interrupted when you on service;

   3.Requirement of Straight pipe

  • The straight of pipe at inlet must more than 10×DN,Suggest 15DN;at outlet,the straight pipe at least 5×DN;
  • If at the upstearm of flowmeter,there are values,elbow,the straight must need 15×DN;
  • Pls installa the shut-off value at both front and behind of flow meter; 

  4.Installation advance

  • The installation location for you reference 
Wall-Mounted Ultrasonic Flow Meter with Lower Price[Company Information]
  • Our Company is Top 10 Manufacture on Made In China;
  • We have about 30 years of experience in Manufacture;
  • Our products have been exported to more 100 coutries and area;
  • ISO,SGS,CE and more ceterficates for you reference;
  • Patent technology and more than 3 years working life
Wall-Mounted Ultrasonic Flow Meter with Lower Price

 

Envoyez votre demande directement à ce fournisseur

*De:
*A:
*Message:

Entrez entre 20 à 4000 caractères.

Ce n'est pas ce que vous recherchez? Publier la Demande d'Achat Maintenant

Vous Aimerez Aussi

Groupes de Produits

Contacter le Fournisseur

Visite Virtuelle à 360

Membre Diamant Depuis 2009

Fournisseurs avec des licences commerciales vérifiées

Société Commerciale
Nombre d'Employés
16
Certification du Système de Gestion
ISO9001:2015